STEP 1
Contact information
STEP 2
Configurator
STEP 3
Send configuration
Reverberation
Anechoic
Semi-anechoic
Special
Existing
New buit
3) Expected external dimensions of the room:
They are given maximum dimensions
YES
NO
Value:
Values are determined by the study:
YES
NO
4) Minimum net internal dimensions of the room:
5) Measured samples
Sample size:
Sample weight:
Estimated measured sound pressure level in dB(A):
CPB analysis of measured samples available:
YES
NO
The sample is physically available for measuring VSB:
YES
NO
Acoustic power
Sound pressure
Sound intensity
Acoustic absorption
Attenuation
Acoustic holography
Class 1, ISO 3745
Class 2, ISO 3744
Class 3, ISO 3746
Other:
50 Hz (octave band center frequency)
63 Hz
80 Hz
100 Hz
125 Hz
160 Hz
200 Hz
250 Hz
Other:
9) The background noise:
Required max. permitted level of background noise in dB (A)
Value:
It requires min. distance from the ambient noise in dB
Value:
Unable to fix => Parameter emerge from the study
10) Ambient noise:
The value of the ambient noise in dB (A) available:
YES
NO
Value dB(A):
CPB analysis of ambient noise available:
YES
NO
The possibility of measuring noise VSB:
YES
NO
11) The size and type of doors:
Description:
Size:
Type of opening:
12) Technological connections inside the chamber necessary for measurement:
NN 230V – quantity, securedí (A):
NN 400V – quantity, secured (A):
Compressed air - quantity, connector type, pressure, source:
Other:
13) Process connections vellum: b>
NN 230V – number of pieces, protection (A):
NN 400V – number of pieces, protection (A):
Compressed air - quantity, connector type, pressure, source:
Other:
14) Mounting panel service connections (Interconnection Chamber> control center): b>
YES
NO
BNC connector - the quantity, type:
JACK - quantity, type:
LEMO - quantity, type:
SPK - quantity, type:
NN terminal - the quantity, type:
LAN connector - the quantity, type:
15) Media: b>
The camera inside the room:
YES
NO
type, resolution, zoom:
Listen in to the room to the control room:
YES
NO
Intercom:
YES
NO
PC:
YES
NO
16) Lighting room: b>
LED
STANDART
STANDART
17) Desired room floor load capacity kg / m 2 sup> b>
18) Ventilation: b>
Ventilation:
YES
NO,
m3/hod:
Cooling:
YES
NO,
Power:
Heating:
YES
NO,
Power:
19) Electromagnetic shielding:
YES
NO,
parameters:
20) Measuring devices: b>
Measuring equipment included:
YES
NO
Type:
Number of microphones:
Number of Channels:
Calibrator:
Verification :
YES
NO
Other
21) Control Room - description, location, amenities: b>
22) Other technologies: b>
Feasibility study
Acoustic project
The total project incl. construction of
Realization
Final measurements
24) Estimated investment: b>
25) Expected timetable: b>
26) Other: