phone +420 597 324 303 e-mail info@avmvision.eu
STEP 1

Contact information

STEP 2

Configurator

STEP 3

Send configuration


Reverberation
Anechoic
Semi-anechoic
Special

Existing
New buit
3) Expected external dimensions of the room:

They are given maximum dimensions

YES

NO

Value:

Values are determined by the study:

YES

NO

4) Minimum net internal dimensions of the room:
5) Measured samples
Sample size:
Sample weight:
Estimated measured sound pressure level in dB(A):
CPB analysis of measured samples available:

YES

NO

The sample is physically available for measuring VSB:

YES

NO


Acoustic power
Sound pressure
Sound intensity
Acoustic absorption
Attenuation
Acoustic holography

Class 1, ISO 3745
Class 2, ISO 3744
Class 3, ISO 3746
Other:

50 Hz (octave band center frequency)
63 Hz
80 Hz
100 Hz
125 Hz
160 Hz
200 Hz
250 Hz
Other:
9) The background noise:
Required max. permitted level of background noise in dB (A)
Value:
It requires min. distance from the ambient noise in dB
Value:
Unable to fix => Parameter emerge from the study
10) Ambient noise:
The value of the ambient noise in dB (A) available:

YES

NO

Value dB(A):
CPB analysis of ambient noise available:

YES

NO

The possibility of measuring noise VSB:

YES

NO

11) The size and type of doors:
Description:
Size:
Type of opening:
12) Technological connections inside the chamber necessary for measurement:
NN 230V – quantity, securedí (A):
NN 400V – quantity, secured (A):
Compressed air - quantity, connector type, pressure, source:
Other:
13) Process connections vellum:
NN 230V – number of pieces, protection (A):
NN 400V – number of pieces, protection (A):
Compressed air - quantity, connector type, pressure, source:
Other:
14) Mounting panel service connections (Interconnection Chamber> control center):
YES

NO

BNC connector - the quantity, type:
JACK - quantity, type:
LEMO - quantity, type:
SPK - quantity, type:
NN terminal - the quantity, type:
LAN connector - the quantity, type:
15) Media:
The camera inside the room:
YES

NO

type, resolution, zoom:
Listen in to the room to the control room:
YES

NO

Intercom:
YES

NO

PC:
YES

NO

16) Lighting room:
LED
STANDART
17) Desired room floor load capacity kg / m 2
18) Ventilation:
Ventilation:

YES

NO,

m3/hod:
Cooling:

YES

NO,

Power:
Heating:

YES

NO,

Power:
19) Electromagnetic shielding:

YES

NO,

parameters:
20) Measuring devices:
Measuring equipment included:
YES

NO

Type:
Number of microphones:
Number of Channels:
Calibrator:
Verification :
YES

NO

Other
21) Control Room - description, location, amenities:
22) Other technologies:

Feasibility study
Acoustic project
The total project incl. construction of
Realization
Final measurements
24) Estimated investment:
25) Expected timetable:
26) Other: